- Products
- Applications
- Online Shop
- Services
- About us
- Contact
Metallic furnaces without fibre insulation are suitable for generating the lowest achievable operation pressures in vacuum operation and the best quality of high purity gas atmospheres.
The used materials are marked for the lowest vapour pressure at the highest temperatures. Caused by the low vapour pressure processes up to the highest temperatures could be work without reactions with the heating elements or insulation radiation shields.
Besides high vacuum operation up to 10-7 mbar the following gases are typically available to use:
Nitrogen, Argon, Hydrogen or mixtures and others on request.
The pressure range to use gases reaches from 10-6 to 1000 mbar absolute and could be controlled by a lot of available dosing and controlling devises.

Molybdenum |
Tungsten |
|||||
|
HBO
10 |
HBO
25 |
HBO
60 |
HBO
10 |
HBO
25 |
HBO
60 |
Outside dimensions |
||||||
WxHxD in mm |
2300 x 2500 x 2000 |
2300 x 2500 x 2000 |
2300 x 2800 x 2500 |
2300 x 2500 x 2000 |
2300 x 2500 x 2000 |
2300 x 2800 x 2500 |
Transport weight |
||||||
complete system in kg |
1800 |
2000 |
3000 |
1800 |
2000 |
3000 |
Useful space |
||||||
using volume in l |
10 |
25 |
60 |
10 |
25 |
60 |
DxH (useful space without retorte) in mm |
200 x 300 |
300 x 400 |
400 x 500 |
200 x 300 |
300 x 400 |
400 x 500 |
DxH (useful space with retorte) in mm |
180 x 280 |
280 x 380 |
380 x 480 |
180 x 280 |
280 x 380 |
380 x 480 |
Thermal values |
||||||
Tmax (vacuum) in °C |
1600 |
1600 |
1600 |
2200 |
2200 |
2200 |
Tmax (atmosphere pressure) in °C |
1600 |
1600 |
1600 |
2200 |
2200 |
2200 |
ΔT (from 800°C) in K (according to DIN 17052) |
+- 10 |
+- 10 |
+- 10 |
+- 10 |
+- 10 |
+- 10 |
max. heating up ramp (up to Tmax) in K/min |
10 |
10 |
10 |
10 |
10 |
10 |
cooling down time in h |
3 |
4 |
5 |
4 |
5 |
6 |
Connecting values |
||||||
power in kW |
50 |
65 |
80 |
125 |
150 |
250 |
voltage in V |
3 x 400 |
3 x 400 |
3 x 400 |
3 x 400 |
3 x 400 |
3 x 400 |
current in A |
3 x 80 |
3 x 100 |
3 x 120 |
2 x 200 |
3 x 220 |
3 x 380 |
leakage rate (clean, cold and empty) in mbar l/s |
5x10-3 |
5x10-3 |
5x10-3 |
5x10-3 |
5x10-3 |
5x10-3 |
Cooling water |
||||||
volume in l/min |
40 |
50 |
64 |
100 |
120 |
200 |
Gas supply |
||||||
Nitrogen or Argon (others on request) in l/h |
500-2000 |
500 - 2000 |
500 - 2000 |
500 - 2000 |
500 - 2000 |
500 - 2000 |
Controller |
SIEMENS S7-300/WIN CC |
SIEMENS S7-300/WIN CC |
SIEMENS S7-300/WIN CC |
SIEMENS S7-300/WIN CC |
SIEMENS S7-300/WIN CC |
SIEMENS S7-300/WIN CC |